38 research outputs found

    Ultrasound, CT, MRI, or PET-CT for staging and re-staging of adults with cutaneous melanoma.

    Get PDF
    BACKGROUND: Melanoma is one of the most aggressive forms of skin cancer, with the potential to metastasise to other parts of the body via the lymphatic system and the bloodstream. Melanoma accounts for a small percentage of skin cancer cases but is responsible for the majority of skin cancer deaths. Various imaging tests can be used with the aim of detecting metastatic spread of disease following a primary diagnosis of melanoma (primary staging) or on clinical suspicion of disease recurrence (re-staging). Accurate staging is crucial to ensuring that patients are directed to the most appropriate and effective treatment at different points on the clinical pathway. Establishing the comparative accuracy of ultrasound, computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET)-CT imaging for detection of nodal or distant metastases, or both, is critical to understanding if, how, and where on the pathway these tests might be used. OBJECTIVES: Primary objectivesWe estimated accuracy separately according to the point in the clinical pathway at which imaging tests were used. Our objectives were:‱ to determine the diagnostic accuracy of ultrasound or PET-CT for detection of nodal metastases before sentinel lymph node biopsy in adults with confirmed cutaneous invasive melanoma; and‱ to determine the diagnostic accuracy of ultrasound, CT, MRI, or PET-CT for whole body imaging in adults with cutaneous invasive melanoma:○ for detection of any metastasis in adults with a primary diagnosis of melanoma (i.e. primary staging at presentation); and○ for detection of any metastasis in adults undergoing staging of recurrence of melanoma (i.e. re-staging prompted by findings on routine follow-up).We undertook separate analyses according to whether accuracy data were reported per patient or per lesion.Secondary objectivesWe sought to determine the diagnostic accuracy of ultrasound, CT, MRI, or PET-CT for whole body imaging (detection of any metastasis) in mixed or not clearly described populations of adults with cutaneous invasive melanoma.For study participants undergoing primary staging or re-staging (for possible recurrence), and for mixed or unclear populations, our objectives were:‱ to determine the diagnostic accuracy of ultrasound, CT, MRI, or PET-CT for detection of nodal metastases;‱ to determine the diagnostic accuracy of ultrasound, CT, MRI, or PET-CT for detection of distant metastases; and‱ to determine the diagnostic accuracy of ultrasound, CT, MRI, or PET-CT for detection of distant metastases according to metastatic site. SEARCH METHODS: We undertook a comprehensive search of the following databases from inception up to August 2016: Cochrane Central Register of Controlled Trials; MEDLINE; Embase; CINAHL; CPCI; Zetoc; Science Citation Index; US National Institutes of Health Ongoing Trials Register; NIHR Clinical Research Network Portfolio Database; and the World Health Organization International Clinical Trials Registry Platform. We studied reference lists as well as published systematic review articles. SELECTION CRITERIA: We included studies of any design that evaluated ultrasound (with or without the use of fine needle aspiration cytology (FNAC)), CT, MRI, or PET-CT for staging of cutaneous melanoma in adults, compared with a reference standard of histological confirmation or imaging with clinical follow-up of at least three months' duration. We excluded studies reporting multiple applications of the same test in more than 10% of study participants. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted all data using a standardised data extraction and quality assessment form (based on the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2)). We estimated accuracy using the bivariate hierarchical method to produce summary sensitivities and specificities with 95% confidence and prediction regions. We undertook analysis of studies allowing direct and indirect comparison between tests. We examined heterogeneity between studies by visually inspecting the forest plots of sensitivity and specificity and summary receiver operating characteristic (ROC) plots. Numbers of identified studies were insufficient to allow formal investigation of potential sources of heterogeneity. MAIN RESULTS: We included a total of 39 publications reporting on 5204 study participants; 34 studies reporting data per patient included 4980 study participants with 1265 cases of metastatic disease, and seven studies reporting data per lesion included 417 study participants with 1846 potentially metastatic lesions, 1061 of which were confirmed metastases. The risk of bias was low or unclear for all domains apart from participant flow. Concerns regarding applicability of the evidence were high or unclear for almost all domains. Participant selection from mixed or not clearly defined populations and poorly described application and interpretation of index tests were particularly problematic.The accuracy of imaging for detection of regional nodal metastases before sentinel lymph node biopsy (SLNB) was evaluated in 18 studies. In 11 studies (2614 participants; 542 cases), the summary sensitivity of ultrasound alone was 35.4% (95% confidence interval (CI) 17.0% to 59.4%) and specificity was 93.9% (95% CI 86.1% to 97.5%). Combining pre-SLNB ultrasound with FNAC revealed summary sensitivity of 18.0% (95% CI 3.58% to 56.5%) and specificity of 99.8% (95% CI 99.1% to 99.9%) (1164 participants; 259 cases). Four studies demonstrated lower sensitivity (10.2%, 95% CI 4.31% to 22.3%) and specificity (96.5%,95% CI 87.1% to 99.1%) for PET-CT before SLNB (170 participants, 49 cases). When these data are translated to a hypothetical cohort of 1000 people eligible for SLNB, 237 of whom have nodal metastases (median prevalence), the combination of ultrasound with FNAC potentially allows 43 people with nodal metastases to be triaged directly to adjuvant therapy rather than having SLNB first, at a cost of two people with false positive results (who are incorrectly managed). Those with a false negative ultrasound will be identified on subsequent SLNB.Limited test accuracy data were available for whole body imaging via PET-CT for primary staging or re-staging for disease recurrence, and none evaluated MRI. Twenty-four studies evaluated whole body imaging. Six of these studies explored primary staging following a confirmed diagnosis of melanoma (492 participants), three evaluated re-staging of disease following some clinical indication of recurrence (589 participants), and 15 included mixed or not clearly described population groups comprising participants at a number of different points on the clinical pathway and at varying stages of disease (1265 participants). Results for whole body imaging could not be translated to a hypothetical cohort of people due to paucity of data.Most of the studies (6/9) of primary disease or re-staging of disease considered PET-CT, two in comparison to CT alone, and three studies examined the use of ultrasound. No eligible evaluations of MRI in these groups were identified. All studies used histological reference standards combined with follow-up, and two included FNAC for some participants. Observed accuracy for detection of any metastases for PET-CT was higher for re-staging of disease (summary sensitivity from two studies: 92.6%, 95% CI 85.3% to 96.4%; specificity: 89.7%, 95% CI 78.8% to 95.3%; 153 participants; 95 cases) compared to primary staging (sensitivities from individual studies ranged from 30% to 47% and specificities from 73% to 88%), and was more sensitive than CT alone in both population groups, but participant numbers were very small.No conclusions can be drawn regarding routine imaging of the brain via MRI or CT. AUTHORS' CONCLUSIONS: Review authors found a disappointing lack of evidence on the accuracy of imaging in people with a diagnosis of melanoma at different points on the clinical pathway. Studies were small and often reported data according to the number of lesions rather than the number of study participants. Imaging with ultrasound combined with FNAC before SLNB may identify around one-fifth of those with nodal disease, but confidence intervals are wide and further work is needed to establish cost-effectiveness. Much of the evidence for whole body imaging for primary staging or re-staging of disease is focused on PET-CT, and comparative data with CT or MRI are lacking. Future studies should go beyond diagnostic accuracy and consider the effects of different imaging tests on disease management. The increasing availability of adjuvant therapies for people with melanoma at high risk of disease spread at presentation will have a considerable impact on imaging services, yet evidence for the relative diagnostic accuracy of available tests is limited

    Effect of 18F-fluciclovine positron emission tomography on the management of patients with recurrence of prostate cancer: Results from the FALCON Trial

    Get PDF
    Purpose: Early and accurate localization of lesions in patients with biochemical recurrence (BCR) of prostate cancer may guide salvage therapy decisions. The present study, 18F-Fluciclovine PET/CT in biochemicAL reCurrence Of Prostate caNcer (FALCON; NCT02578940), aimed to evaluate the effect of 18F-fluciclovine on management of men with BCR of prostate cancer. Methods and Materials: Men with a first episode of BCR after curative-intent primary therapy were enrolled at 6 UK sites. Patients underwent 18F-fluciclovine positron emission tomography/computed tomography (PET/CT) according to standardized procedures. Clinicians documented management plans before and after scanning, recording changes to treatment modality as major and changes within a modality as other. The primary outcome measure was record of a revised management plan postscan. Secondary endpoints were evaluation of optimal prostate specific antigen (PSA) threshold for detection, salvage treatment outcome assessment based on 18F-fluciclovine-involvement, and safety. Results: 18F-Fluciclovine was well tolerated in the 104 scanned patients (median PSA = 0.79 ng/mL). Lesions were detected in 58 out of 104 (56%) patients. Detection was broadly proportional to PSA level; ≀1 ng/mL, 1 out of 3 of scans were positive, and 93% scans were positive at PSA >2.0 ng/mL. Sixty-six (64%) patients had a postscan management change (80% after a positive result). Major changes (43 out of 66; 65%) were salvage or systemic therapy to watchful waiting (16 out of 66; 24%); salvage therapy to systemic therapy (16 out of 66; 24%); and alternative changes to treatment modality (11 out of 66, 17%). The remaining 23 out of 66 (35%) management changes were modifications of the prescan plan: most (22 out of 66; 33%) were adjustments to planned brachytherapy/radiation therapy to include a 18F-fluciclovine-guided boost. Where 18F-fluciclovine guided salvage therapy, the PSA response rate was higher than when 18F-fluciclovine was not involved (15 out of 17 [88%] vs 28 out of 39 [72%]). Conclusions: 18F-Fluciclovine PET/CT located recurrence in the majority of men with BCR, frequently resulting in major management plan changes. Incorporating 18F-fluciclovine PET/CT into treatment planning may optimize targeting of recurrence sites and avoid futile salvage therapy

    Alterations in anatomic and functional imaging parameters with repeated FDG PET-CT and MRI during radiotherapy for head and neck cancer: a pilot study

    Get PDF
    Background: The use of imaging to implement on-treatment adaptation of radiotherapy is a promising paradigm but current data on imaging changes during radiotherapy is limited. This is a hypothesis-generating pilot study to examine the changes on multi-modality anatomic and functional imaging during (chemo)radiotherapy treatment for head and neck squamous cell carcinoma (HNSCC). Methods: Eight patients with locally advanced HNSCC underwent imaging including computed tomography (CT), Fluorine-18 fluorodeoxyglucose (FDG) positron emission tomography (PET)-CT and magnetic resonance imaging (MRI) (including diffusion weighted (DW) and dynamic contrast enhanced (DCE)) at baseline and during (chemo)radiotherapy treatment (after fractions 11 and 21). Regions of interest (ROI) were drawn around the primary tumour at baseline and during treatment. Imaging parameters included gross tumour volume (GTV) assessment, SUVmax, mean ADC value and DCE-MRI parameters including Plasma Flow (PF). On treatment changes and correlations between these parameters were analysed using a Wilcoxon rank sum test and Pearson’s linear correlation coefficient respectively. A p-value <0.05 was considered statistically significant. Results: Statistically significant reductions in GTV-CT, GTV-MRI and GTV-DW were observed between all imaging timepoints during radiotherapy. Changes in GTV-PET during radiotherapy were heterogeneous and non-significant. Significant changes in SUVmax, mean ADC value, Plasma Flow and Plasma Volume were observed between the baseline and the fraction 11 timepoint, whilst only changes in SUVmax between baseline and the fraction 21 timepoint were statistically significant. Significant correlations were observed between multiple imaging parameters, both anatomical and functional; 20 correlations between baseline to the fraction 11 timepoint; 12 correlations between baseline and the fraction 21 timepoints; and 4 correlations between the fraction 11 and fraction 21 timepoints. Conclusions: Multi-modality imaging during radiotherapy treatment demonstrates early changes (by fraction 11) in both anatomic and functional imaging parameters. All functional imaging modalities are potentially complementary and should be considered in combination to provide multi-parametric tumour assessment, to guide potential treatment adaptation strategies. Trial Registration: ISRCTN Registry: ISRCTN34165059. Registered 2nd February 2015

    Efficacy of therapist-delivered transdiagnostic CBT for patients with persistent physical symptoms in secondary care: a randomised controlled trial

    Get PDF
    Background: Medically unexplained symptoms otherwise referred to as persistent physical symptoms (PPS) are debilitating to patients. As many specific PPS syndromes share common behavioural, cognitive, and affective influences, transdiagnostic treatments might be effective for this patient group. We evaluated the clinical efficacy and cost-effectiveness of a therapist-delivered, transdiagnostic cognitive behavioural intervention (TDT-CBT) plus (+) standard medical care (SMC) v. SMC alone for the treatment of patients with PPS in secondary medical care. Methods: A two-arm randomised controlled trial, with measurements taken at baseline and at 9, 20, 40- and 52-weeks post randomisation. The primary outcome measure was the Work and Social Adjustment Scale (WSAS) at 52 weeks. Secondary outcomes included mood (PHQ-9 and GAD-7), symptom severity (PHQ-15), global measure of change (CGI), and the Persistent Physical Symptoms Questionnaire (PPSQ). Results: We randomised 324 patients and 74% were followed up at 52 weeks. The difference between groups was not statistically significant for the primary outcome (WSAS at 52 weeks: estimated difference -1.48 points, 95% confidence interval from -3.44 to 0.48, p = 0.139). However, the results indicated that some secondary outcomes had a treatment effect in favour of TDT-CBT + SMC with three outcomes showing a statistically significant difference between groups. These were WSAS at 20 weeks (p = 0.016) at the end of treatment and the PHQ-15 (p = 0.013) and CGI at 52 weeks (p = 0.011). Conclusion: We have preliminary evidence that TDT-CBT + SMC may be helpful for people with a range of PPS. However, further study is required to maximise or maintain effects seen at end of treatment

    Proceedings of the International Cancer Imaging Society (ICIS) 16th Annual Teaching Course

    Full text link
    Table of contents O1 Tumour heterogeneity: what does it mean? Dow-Mu Koh O2 Skeletal sequelae in adult survivors of childhood cancer Sue Creviston Kaste O3 Locoregional effects of breast cancer treatment Sarah J Vinnicombe O4 Imaging of cancer therapy-induced CNS toxicity Giovanni Morana, Andrea Rossi O5 Screening for lung cancer Christian J. Herold O6Risk stratification of lung nodules Theresa C. McLoud O7 PET imaging of pulmonary nodules Kirk A Frey O8 Transarterial tumour therapy Bernhard Gebauer O9 Interventional radiology in paediatric oncology Derek Roebuck O10 Image guided prostate interventions Jurgen J. FĂŒtterer O11 Imaging cancer predisposition syndromes Alexander J. Towbin O12Chest and chest wall masses Thierry AG Huisman O13 Abdominal masses: good or bad? Anne MJB Smets O14 Hepatobiliary MR contrast: enhanced liver MRI for HCC diagnosis and management Giovanni Morana O15 Role of US elastography and multimodality fusion for managing patients with chronic liver disease and HCC Jeong Min Lee O16 Opportunities and challenges in imaging metastatic disease Hersh Chandarana O17 Diagnosis, treatment monitoring, and follow-up of lymphoma Marius E. Mayerhoefer, Markus Raderer, Alexander Haug O18 Managing high-risk and advanced prostate cancer Matthias Eiber O19 Immunotherapy: imaging challenges Bernhard Gebauer O20 RECIST and RECIST 1.1 Andrea Rockall O21 Challenges of RECIST in oncology imaging basics for the trainee and novice Aslam Sohaib O22 Lymphoma: PET for interim and end of treatment response assessment: a users’ guide to the Deauville Score Victoria S Warbey O23 Available resources Hebert Alberto Vargas O24 ICIS e-portal and the online learning community Dow-Mu Koh O25 Benign lesions that mimic pancreatic cancer Jay P Heiken O26 Staging and reporting pancreatic malignancies Isaac R Francis, Mahmoud, M Al-Hawary, Ravi K Kaza O27 Intraductal papillary mucinous neoplasm Giovanni Morana O28 Cystic pancreatic tumours Mirko D’Onofrio O29 Diffusion-weighted imaging of head and neck tumours Harriet C. Thoeny O30 Radiation injury in the head and neck Ann D King O31 PET/MR of paediatric brain tumours Giovanni Morana, Arnoldo Piccardo, Maria Luisa GarrĂš, Andrea Rossi O32 Structured reporting and beyond Hebert Alberto Vargas O33 Massachusetts General Hospital experience with structured reporting Theresa C. McLoud O34 The oncologist’s perspective: what the oncologist needs to know Nick Reed O35 Towards the cure of all children with cancer: global initiatives in pediatric oncology Carlos Rodriguez-Galindo O36 Multiparametric imaging of renal cancers Hersh Chandarana O37 Linking imaging features of renal disease and their impact on management strategies Hebert Alberto Vargas O38 Adrenals, retroperitoneum and peritoneum Isaac R Francis, Ashish P Wasnik O39 Lung and pleura Stefan Diederich O40 Advances in MRI Jurgen J. FĂŒtterer O41 Advances in molecular imaging Wim J.G. Oyen O42 Incorporating advanced imaging, impact on treatment selection and patient outcome Cheng Lee Chaw, Nicholas van As S1 Combining ADC-histogram features improves performance of MR diffusion-weighted imaging for Lymph node characterisation in cervical cancer Igor Vieira, Frederik De Keyzer, Elleke Dresen, Sileny Han, Ignace Vergote, Philippe Moerman, Frederic Amant, Michel Koole, Vincent Vandecaveye S2 Whole-body diffusion-weighted MRI for surgical planning in patients with colorectal cancer and peritoneal metastases R Dresen, S De Vuysere, F De Keyzer, E Van Cutsem, A D’Hoore, A Wolthuis, V Vandecaveye S3 Role of apparent diffusion coefficient (ADC) diffusion-weighted MRI for predicting extra capsular extension of prostate cancer. P. Pricolo ([email protected]), S. Alessi, P. Summers, E. Tagliabue, G. Petralia S4 Generating evidence for clinical benefit of PET/CT – are management studies sufficient as surrogate for patient outcome? C. Pfannenberg, B. GĂŒckel, SC SchĂŒle, AC MĂŒller, S. Kaufmann, N. Schwenzer, M. Reimold,C. la Fougere, K. Nikolaou, P. Martus S5 Heterogeneity of treatment response in skeletal metastases from breast cancer with 18F-fluoride and 18F-FDG PET GJ Cook, GK Azad, BP Taylor, M Siddique, J John, J Mansi, M Harries, V Goh S6 Accuracy of suspicious breast imaging—can we tell the patient? S Seth, R Burgul, A Seth S7 Measurement method of tumour volume changes during neoadjuvant chemotherapy affects ability to predict pathological response S Waugh, N Muhammad Gowdh, C Purdie, A Evans, E Crowe, A Thompson, S Vinnicombe S8 Diagnostic yield of CT IVU in haematuria screening F. Arfeen, T. Campion, E. Goldstraw S9 Percutaneous radiofrequency ablation of unresectable locally advanced pancreatic cancer: preliminary results D’Onofrio M, Ciaravino V, Crosara S, De Robertis R, Pozzi Mucelli R S10 Iodine maps from dual energy CT improve detection of metastases in staging examinations of melanoma patients M. Uhrig, D. Simons, H. Schlemmer S11Can contrast enhanced CT predict pelvic nodal status in malignant melanoma of the lower limb? Kate Downey S12 Current practice in the investigation for suspected Paraneoplastic Neurological Syndromes (PNS) and positive malignancy yield. S Murdoch, AS Al-adhami, S Viswanathan P1 Technical success and efficacy of Pulmonary Radiofrequency ablation: an analysis of 207 ablations S Smith, P Jennings, D Bowers, R Soomal P2 Lesion control and patient outcome: prospective analysis of radiofrequency abaltion in pulmonary colorectal cancer metastatic disease S Smith, P Jennings, D Bowers, R Soomal P3 Hepatocellular carcinoma in a post-TB patient: case of tropical infections and oncologic imaging challenges TM Mutala, AO Odhiambo, N Harish P4 Role of apparent diffusion coefficient (ADC) diffusion-weighted MRI for predicting extracapsular extension of prostate cancer P. Pricolo, S. Alessi, P. Summers, E. Tagliabue, G. Petralia P5 What a difference a decade makes; comparison of lung biopsies in Glasgow 2005 and 2015 M. Hall, M. Sproule, S. Sheridan P6 Solid pseudopapillary tumour of pancreas: imaging features of a rare neoplasm KY Thein, CH Tan, YL Thian, CM Ho P7 MDCT - pathological correlation in colon adenocarcinoma staging: preliminary experience S De Luca, C Carrera, V Blanchet, L AlarcĂłn, E Eyheremnedy P8 Image guided biopsy of thoracic masses and reduction of pneumothorax risk: 25 years experience B K Choudhury, K Bujarbarua, G Barman P9 Tumour heterogeneity analysis of 18F-FDG-PET for characterisation of malignant peripheral nerve sheath tumours in neurofibromatosis-1 GJ Cook, E Lovat, M Siddique, V Goh, R Ferner, VS Warbey P10 Impact of introduction of vacuum assisted excision (VAE) on screen detected high risk breast lesions L Potti, B Kaye, A Beattie, K Dutton P11 Can we reduce prevalent recall rate in breast screening? AA Seth, F Constantinidis, H Dobson P12 How to reduce prevalent recall rate? Identifying mammographic lesions with low Positive Predictive Value (PPV) AA Seth ([email protected]), F Constantinidis, H Dobson P13 Behaviour of untreated pulmonary thrombus in oncology patients diagnosed with incidental pulmonary embolism on CT R. Bradley, G. Bozas, G. Avery, A. Stephens, A. Maraveyas P14 A one-stop lymphoma biopsy service – is it possible? S Bhuva, CA Johnson, M Subesinghe, N Taylor P15 Changes in the new TNM classification for lung cancer (8th edition, effective January 2017) LE Quint, RM Reddy, GP Kalemkerian P16 Cancer immunotherapy: a review of adequate imaging assessment G GonzĂĄlez Zapico, E Gainza Jauregui, R Álvarez Francisco, S Ibåñez Alonso, I Tavera Bahillo, L MĂșgica Álvarez P17 Succinate dehydrogenase mutations and their associated tumours O Francies, R Wheeler, L Childs, A Adams, A Sahdev P18 Initial experience in the usefulness of dual energy technique in the abdomen SE De Luca, ME Casalini Vañek, MD Pascuzzi, T Gillanders, PM Ramos, EP Eyheremendy P19 Recognising the serious complication of Richter’s transformation in CLL patients C Stove, M Digby P20 Body diffusion-weighted MRI in oncologic practice: truths, tricks and tips M. Nazar, M. Wirtz, MD. Pascuzzi, F. Troncoso, F. Saguier, EP. Eyheremendy P21 Methotrexate-induced leukoencephalopathy in paediatric ALL Patients D.J. Quint, L. Dang, M. Carlson, S. Leber, F. Silverstein P22 Pitfalls in oncology CT reporting. A pictorial review R Rueben, S Viswanathan P23 Imaging of perineural extension in head and neck tumours B Nazir, TH Teo, JB Khoo P24 MRI findings of molecular subtypes of breast cancer: a pictorial primer K Sharma, N Gupta, B Mathew, T Jeyakumar, K Harkins P25 When cancer can’t wait! A pictorial review of oncological emergencies K Sharma, B Mathew, N Gupta, T Jeyakumar, S Joshua P26 MRI of pancreatic neuroendocrine tumours: an approach to interpretation D Christodoulou, S Gourtsoyianni, A Jacques, N Griffin, V Goh P27 Gynaecological cancers in pregnancy: a review of imaging CA Johnson, J Lee P28 Suspected paraneoplastic neurological syndromes - review of published recommendations to date, with proposed guideline/flowchart JA Goodfellow, AS Al-adhami, S Viswanathan P29 Multi-parametric MRI of the pelvis for suspected local recurrence of prostate cancer after radical prostatectomy R Bradley P30 Utilisation of PI-RADS version 2 in multi-parametric MRI of the prostate; 12-months experience R Bradley P31 Radiological assessment of the post-chemotherapy liver A Yong, S Jenkins, G Joseph P32 Skeletal staging with MRI in breast cancer – what the radiologist needs to know S Bhuva, K Partington P33 Perineural spread of lympoma: an educational review of an unusual distribution of disease CA Johnson, S Bhuva, M Subesinghe, N Taylor P34 Visually isoattenuating pancreatic adenocarcinoma. Diagnostic imaging tools. C Carrera, A Zanfardini, S De Luca, L AlarcĂłn, V Blanchet, EP Eyheremendy P35 Imaging of larynx cancer: when is CT, MRI or FDG PET/CT the best test? K Cavanagh, E Lauhttp://deepblue.lib.umich.edu/bitstream/2027.42/134651/1/40644_2016_Article_79.pd

    Multi-observer concordance and accuracy of the British Thoracic Society scale and other visual assessment qualitative criteria for solid pulmonary nodule assessment using FDG PET-CT

    Get PDF
    AIM: To compare the interobserver reliability and diagnostic accuracy of the British Thoracic Society (BTS) scale and other visual assessment criteria in the context of 2-[ 18F]-fluoro-2-deoxy- d-glucose (FDG) positron-emission tomography (PET)-computed tomography (CT) evaluation of solid pulmonary nodules (SPNs). MATERIALS AND METHODS: Fifty patients who underwent FDG PET-CT for assessment of a SPN were identified. Seven reporters with varied experience at four centres graded FDG uptake visually using the British Thoracic Society (BTS) four-point scale. Five reporters also scored SPNs according to three- and five-point visual assessment scales and using semi-quantitative assessment (maximum standardised uptake value [SUV max]). Interobserver reliability was assessed with the intra-class correlation coefficient (ICC) and weighted Cohen's kappa (Îș). Diagnostic performance was evaluated by receiver operator characteristic (ROC) analysis. RESULTS: Good interobserver reliability was demonstrated with the BTS scale (ICC=0.78, 95% confidence interval [CI]: 0.69–0.85) and five-point scale (ICC=0.78, 95 CI 0.68–0.86), whilst the three-point scale demonstrated moderate reliability (ICC=0.70, 95% CI: 0.59–0.80). Almost perfect agreement was achieved between two consultants (Îș=0.85), and substantial agreement between two other consultants (Îș=0.78) using the BTS scale. ROC curves for the BTS and five-point scales demonstrated equivalent accuracy (BTS area under the ROC curve [AUC]=0.768; five-point AUC=0.768). SUV max was no more accurate compared to the BTS scale (SUV max AUC=0.794; BTS AUC=0.768, p=0.43). CONCLUSIONS: The BTS scale can be applied reliably by reporters with varied levels of PET-CT reporting experience, across different centres and has a diagnostic performance that is not surpassed by alternative scales

    18F-FDG PET/CT Detected Delayed Endoleak in an Aortoiliac Endovascular Aneurysm Repair

    Get PDF
    We present a case of a type Ia endoleak detected using 18F-FDG PET/CT 10 years after an abdominal aortoiliac endovascular aneurysm repair in an 83-year-old man. The 18F-FDG PET/CT scan was performed to evaluate a solitary pulmonary nodule but, in addition, demonstrated unexpected blood pool activity outside the stent graft and within the abdominal aortic aneurysm sac, indicating an endoleak; no FDG activity should be present within the aneurysm sac after stent graft placement. A subsequent CT angiogram confirmed the endoleak. This case illustrates the value of PET/CT in unexpectedly demonstrating this serious, late complication of endovascular aneurysm repair
    corecore